Test your knowledge in Building Envelope, HVAC, Lighting, Energy Management, Building Code and Standards
Building Envelope
|
In an ECBC 2017 compliant commercial building which
has 40% Window to Wall Ratio, the maximum amount of heat gain
(per-square-foot) will occur through: |
||||
|
A |
Walls |
B |
Windows |
|
|
C |
Roof |
D |
Floor |
|
|
Which of the following statement is NOT
correct? |
||||
|
A |
Lower R-values means better insulation |
B |
Thermal
mass does not equate to better insulation |
|
|
C |
Heat gain increases with extreme outdoor
temperatures |
D |
Lower U-factors mean better insulation |
|
|
From the following glass specifications, which
combination shows high performance glass properties? |
||||
|
A |
SHGC = 0.4, VLT = 0.4, U-value = 5.2 W/m2-k |
B |
SHGC = 0.4, VLT = 0.6, U-value = 5.2 W/m2-k |
|
|
C |
SHGC = 0.3, VLT = 0.4, U-value = 2.0 W/m2-k |
D |
SHGC = 0.8, VLT = 0.82 U-value = 5.8 W/m2-k |
|
|
Which of the following is NOT true with regard
to “Cool Roof”? |
||||
|
A |
Cool roof exhibits low Solar Reflectance Index
(SRI) |
B |
Cool roof tends to emit heat at a high rate |
|
|
C |
Usually cool roof exhibits a high Solar
Reflectance Index |
D |
Cool roof is used to mitigate UHI (Urban
Heat Island) effect |
|
|
Higher the heat gain larger the capacity of cooling
(air-conditioning) system. From the below list, which combination does not increase
the heat gain? |
||||
|
A |
Wall, roof, window and lighting |
B |
Building envelope, lighting, occupant and
equipment |
|
|
C |
Wall, roof, window and occupant |
D |
Office Furniture and exterior lighting system |
|
|
Intent to study the building size and shape is
to ? |
||||
|
A |
Optimize energy performance |
B |
Enhance daylighting |
|
|
C |
Improve ventilation |
D |
All of the above |
|
|
If a building is located in a Cold Climatic
Zone of India (example Shimla), select a suitable measure that can enhance
building energy efficiency? |
||||
|
A |
Low SHGC and high U-value |
B |
Low SHGC and low U-value |
|
|
C |
High SHGC and high U-value |
D |
High SHGC and low U-value |
|
|
In tropical climate like India, preferred orientation for reducing
heat gain in a building is: |
||||
|
A |
East-West |
B |
North-South |
|
|
C |
Does not matter et al. |
D |
Provide buffer spaces in South |
|
|
What is the relation between U-value (overall
heat transfer coefficient) and R-value (thermal resistance) ? |
||||
|
A |
U-value is reciprocal of R-value |
B |
U-value is proportional to R-value |
|
|
C |
R = L/K |
D |
Q = UA Delta-T |
|
|
Select the high-performance wall option from
below choices: |
||||
|
A |
200 mm Red brick wall |
B |
200 mm concrete wall |
|
|
C |
200 mm Flay ash Brick wall |
D |
200 mm AAC Block wall |
|
|
SHGC of a 3 mm clear glass is 0.87. If the
SHGC of a given glass is 0.5 then what is the value of Shading Coefficient
(SC)? |
||||
|
A |
0 |
B |
1.0 |
|
|
C |
0.57 |
D |
1.57 |
|
|
Which one is recommended for roof insulation
in a tropical climate? |
||||
|
A |
Over deck insulation |
B |
Under deck insulation |
|
|
C |
Sandwich insulation |
D |
Does not matter |
|
|
Light Shelf helps to control
the following? |
||||
|
A |
Heat Gain |
B |
Light |
|
|
C |
Glare |
D |
Both Heat Gain and Glare |
|
|
From the following properties
of building material, which property relates to thermal mass? |
||||
|
A |
Thermal conductivity (k) |
B |
Specific heat of material (Cp) |
|
|
C |
Solar reflectivity (r) |
D |
Emissivity (e) |
|
|
Which one of the following
is not a passive cooling strategy? |
||||
|
A |
Wind tower and Solar chimney |
B |
Geothermal and earth air tunnel |
|
|
C |
Window shade and self-shading |
D |
Evaporative/ Desert cooling |
|
|
Which Standard defines the
requirements for minimum fresh air ventilation? |
||||
|
A |
ASHRAE 90.1 |
B |
ASHRAE 62.1 |
|
|
C |
ECBC 2017 |
D |
ASHRAE 55 |
|
|
An air-conditioned room
which has two lighting fixtures: an incandescent bulb of 100 W (used 10
hours/day) and LED lamp of 20 W (used for 10 hours/day), find out the
lighting power installed? |
||||
|
A |
1.2 kWh |
B |
120 W |
|
|
C |
1200 W |
D |
12 kWh |
|
|
What is the minimum connected
load or contract demand for a commercial building to demonstrate compliance
for ECBC 2017? |
||||
|
A |
100 kW or 120
kVA |
B |
1000 kW or
1200 kVA |
|
|
C |
100 kWh or 120
kVA |
D |
500 kW or 600
kVA |
|
|
Which climatic zone is not
listed in the National Building Code of India 2016: |
||||
|
A |
Hot and Dry
Climate |
B |
Warm and Humid
|
|
|
C |
Temperate |
D |
Cold and Humid |
|
|
Main objective
of using IPMVP (International Performance Monitoring and Verification
Protocol) for green buildings is to: |
||||
|
A |
Optimise
energy use |
B |
Verify
envisaged energy performance |
|
|
C |
Optimise
overall building performance |
D |
Target reduction in carbon emission |
|
|
An office building of 100
sq m area is located in Mumbai. Annual and lighting energy Consumption are
10,000 kWh and 2,000 kWh, respectively. What is the Energy Performance Index
(EPI) of the building? |
||||
|
A |
100 kWh/sq m |
B |
120 kWh/sq m |
|
|
C |
80 kWh/sq m |
D |
None of the above |
|
|
Intent of carrying out
energy simulation for green buildings is ? |
||||
|
A |
Reduce energy consumption |
B |
Evaluate energy performance of the building |
|
|
C |
Reduce equipment load |
D |
Reduce green house gas emission |
|
|
A building
of 1000 sq ft built-up area and lighting load is 1 kW, what is the level of
LPD (Lighting Power Density) following building area method ? |
||||
|
A |
0.001 W/sq ft |
B |
10 W/sq m |
|
|
C |
1 W/sq ft |
D |
1 W/ sq m |
|
|
What are
the two methods being followed for calculating the base case LPD (Lighting
Power Density) as per the ASHRAE 90.1 Standard ? |
||||
|
A |
Building Area
Method & Space-by-Area Method |
B |
Floor Area Method & Space-by-Space Method |
|
|
C |
Building Area Method & Whole Building
Performance Method |
D |
Space-by-space
Method & Whole Building Performance Method |
|
|
CFL based lighting fixtures have been replaced by
LED based lighting fixtures in an office building. What is the overall effect
of the renovation on energy usage? |
||||
|
A |
Annual energy consumption
would not change |
B |
Lighting energy consumption
would reduce |
|
|
C |
Cooling energy consumption
would decrease |
D |
Both lighting and cooling energy
consumption would reduce |
|
|
Which light source has the
lowest Luminous Efficacy (Lumens per W) |
||||
|
A |
CFL Light |
B |
LED Light |
|
|
C |
Incandescent bulb |
D |
Fluorescent Tube light |
|
|
Lumen/watt is the unit of: |
||||
|
A |
Light flux |
B |
Brightness |
|
|
C |
Luminous intensity |
D |
Luminous efficacy |
|
|
Lumen/watt is the unit of: |
||||
|
A |
Light flux |
B |
Brightness |
|
|
C |
Luminous intensity |
D |
Luminous efficacy |
|
|
Illuminance of a surface is
expressed in : |
||||
|
A |
Radians |
B |
lumens |
|
|
C |
Lux |
D |
LPD |
|
|
What is the recommended
lighting level (lux) for an office building to achieve visual comfort ? |
||||
|
A |
110 – 200 lux |
B |
110 – 2000 lux |
|
|
C |
250 – 350 lux |
D |
More than 1000 lux |
|
|
One ton of refrigeration is
not equal to __ |
||||
|
A |
3024 kCal/hr |
B |
3.51 kW |
|
|
C |
12000 Btu/hr |
D |
860 kCal/hr |
|
|
Energy performance index
(EPI = kWh/square meter/year) is defined as: |
||||
|
A |
Annual
energy consumption/
Total Built-up area |
B |
Annual energy consumption/ Total carpet area |
|
|
C |
Annual
energy consumption/
Site area |
D |
Annual energy consumption/ Total roof area |
|
|
Energy performance index
(EPI = kWh/square meter/year) is a ratio of annual building energy
consumption to : |
||||
|
A |
Total
built-up area |
B |
Total
carpet
area |
|
|
C |
Site
area |
D |
Roof area |
|
|
Coefficient
of Performance (COP) is a ratio of : |
||||
|
A |
Desired cooling effect/ Work
Input |
B |
Desired cooling effect/
Heat input |
|
|
C |
Cooling load/ heat Input |
D |
All of the above |
|
|
Which
component is not part of vapor compression (air-conditioning) system? |
||||
|
A |
Compressor |
B |
Evaporator |
|
|
C |
Condenser |
D |
Pump |
|
|
COP
is defined as T1 /(T2-T1) wherein T1 represents evaporator temperature in K
and T2 shows condenser temperature in K). How cop can be increased ? |
||||
|
A |
Lower
evaporator temperature and higher condenser temperature |
B |
Higher
evaporator temperature and Lower condenser temperature |
|
|
C |
Higher
evaporator temperature and higher condenser temperature |
D |
Lower
evaporator temperature and Lower condenser temperature |
|
|
The
value of COP in vapour compression system is usually |
||||
|
A |
Always
less than unity |
B |
Always
more than unity |
|
|
C |
Equal
to unity |
D |
Any
one of the above |
|
|
The
relation between COP and kW/TR for a refrigeration system is given by |
||||
|
A |
kW/TR
= 3.516/COP |
B |
kW/TR
= COP /3.516 |
|
|
C |
kW/TR
= 860/COP |
D |
none
of the above |
|
|
The
relation between COP and kW/TR for a refrigeration system is given by |
||||
|
A |
kW/TR
= 3.516/COP |
B |
kW/TR
= COP /3.516 |
|
|
C |
kW/TR
= 860/COP |
D |
none
of the above |
|
|
One
ton of refrigeration is equal to the refrigeration effect corresponding to
melting of 1000 kg (one Ton) of ice in : |
||||
|
A |
1
hour |
B |
8
hours |
|
|
C |
12
hours |
D |
24
hours |
|